What was found
DURING C-CHECK INSPECTION FOUND 1 BOLT SHEARED AND RUSTED, AND 1 BOLT RUSTED AT RT WING ROOT FUSELAGE ANGLE. FUSELAGE STA 1371. REAMED HOLES, EDDY CURRENT INSPECTION ACCOMPLISHED, MFG AND INSTALLED TAPERED WASHERS, TREAT, PRIME, SEAL AND PAINT IAW ENGINEERING REPAIR. (K)