What was found
DURING A6-CHECK IN ATL INSPECTION FOUND CORROSION ON WING CENTER SECTION SKIN AT FWD OUTBOARD CORNER OF LT MLG WHEEL WELL. REMOVED CORROSION PER SRM 57-20-00 FIG 21. DRILLED UP AND INSTALLED NEW ANGLE (ANB7392-1) PER SRM 57-20-00 FIG 21. LEAK CHECKED OK. DRILLED UP AND INSTALLED LOWER SUPPORT (AEA7284-1). CLEANED OUT TANK. INSTALLED 2 EA INTERNAL TANK ACCESS PANELS. INSTALLED ACCESS PLATES. LEAK CHECKED OK.