What was found
DURING C3 CHECK IN TPE INSPECTION FOUND DEFORM ON THE GND JACKS SUPPORT BRACKET INSIDE OF RT WING FUELING STATION (REF EGAT N/R U05025). REMOVED BRACKET IAW SRM 51-35-01 VOL 2 REV 40, FABRICATED SUPPORT BRACKET IAW EGAT EI W2009P57B-350 REV 00, INSTALLED THIS SUPPORT BRACKET IAW SRM 51-35-01 VOL 2 REV 40, AND JOB COMPLETE & COND CHK NORM.