What was found
DURING C3 CHECK IN TPE INSPECTION FOUND CRACK ON FLIPPER DOOR FWD EDGE OF RT MLG GR - ABOUT .5 INCH (REF EGAT N/R U05029). REMOVED THIS CRACKED FLIPPER DOOR PER AMM 32-14-08-000-801, REPAIRED THE FLIPPER DOOR IAW SRM VOL 1 52-10-00 FIG 18 REV 40, REINSTALLED AND SWING TEST FOR FLIPPER DOOR REFER TO JOB CARD ATTACHING SHEET 079555 ITEM 2 & 3 AND JOB COMPLETE AND CHECKED NORMAL.