What was found
DURING C-CHK IN TPE INSPECTION FOUND THE RIGHT WING FUEL ACCESS CHANNEL CRACKED AT F/ACCESS PNL 633AT, 634BT, 636AB, 636BB, 636CB, & 638DB (REF EGAT NRC U05081). REPLACED THE DAMAGED CHANNELS AND RUB STRIP AT F/ACCESS PNLS 633AT, 634BT, 636AB, 636BB, 636CB, & 638DB IAW MD-11F SRM VOL 2 51-42-04 FIG 4 REV 40. RE-INSTALLED SEALANT TO F/ACCESS PNLS 634CT, 637AB, 638AB, 638BB, & 638CB IAW MD-11F SRM VOL 2 51-41-01 REV 40. COND CHECK NORMAL & JOB COMPLETE.