As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHK IN TPE INSPECTION FOUND STEP PANEL CRACKED IN AVIONICS COMP FWD CORNER OF LADDER - SIDE PANEL AT STA 348 (REF EGAT NRC U05042). PER AMM 20-50-02-900-801 / 910-801 REV 63 REPLACED THE STEP COVER. CONDITION CHECK NORMAL & JOB COMPLETE.