What was found
DURING C-CHK IN TPE MX/INSP FOUND CORROSION CENTER CARGO LONGERON 46R HAS CORROSION AT STA 5-73. REPAIRED CORRODED AREA IAW EGAT EI W2009A53B-697 REV 00. CONDITION CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHK IN TPE MX/INSP FOUND CORROSION CENTER CARGO LONGERON 46R HAS CORROSION AT STA 5-73. REPAIRED CORRODED AREA IAW EGAT EI W2009A53B-697 REV 00. CONDITION CHECK NORMAL.