What was found
CRACK - CRACK WAS FOUND ON ANGLE OF LT SEAL RETAINER SUPPORT BEAM NR 2 FLAP TRACK MOVABLE FAIRING. FABRICATE AND INSTALL NEW STIFFENER PER DWG 314T4210.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK - CRACK WAS FOUND ON ANGLE OF LT SEAL RETAINER SUPPORT BEAM NR 2 FLAP TRACK MOVABLE FAIRING. FABRICATE AND INSTALL NEW STIFFENER PER DWG 314T4210.