What was found
AFTER PUSHBACK FROM GATE, DURING ENG START, FLT CREW NOTED LOSS OF NR 2 ENG OIL PRESS IND ALONG WITH LOSS OF N1 AND OIL TEMPERATURE IND. FLT CREW SHUT DOWN NR 2 ENG AND TAXIED BACK TO GATE W/O FURTHER INCIDENT. MX TROUBLE SHOOTING LEAD MX PERSONNEL TO BELIEVE THAT NR 2 GENERATOR WAS DROPPING OFF LINE. MAINTENANCE PERSONNEL TROUBLE SHOT NR 2 INTEGRATED DRIVE GENERATOR (IDG), AND FOUND IT WAS OVER SERVICED WITH OIL. IDG WAS DRAINED OF ALL OIL. OIL FILTERS WERE REMOVED AND INSPECTED (NO CONTAMINATION FOUND), AND REINSTALLED. IDG WAS SERVICED TO THE CORRECT LEVEL. NR 2 ENGINE WAS GROUND RUN TO CHECK NR 2 IDG. NO FAULTS FOUND AND ALL ENGINE PARAMETERS WERE NORMAL. AIRCRAFT WAS RETURNED TO SERVICE. (M)