What was found
CABIN BS 495 RBL 30 TO 60 FLOOR PANEL SUPPORT FOUND FASTENER HOLE VICINITY WITH CORROSION. CORROSION REMOVED AND REPROTECTED AS PER MD-11 SRM VOL 51-21-01 REV 20. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN BS 495 RBL 30 TO 60 FLOOR PANEL SUPPORT FOUND FASTENER HOLE VICINITY WITH CORROSION. CORROSION REMOVED AND REPROTECTED AS PER MD-11 SRM VOL 51-21-01 REV 20. (M)