What was found
DURING C-CHECK, FOUND 3 DENTS IN FUSELAGE SKIN AT STA 265 BETWEEN STR 10A L AND 11L. REMOVED DAMAGED, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-30-03 FIG 1. THIS IS A CATEGORY -C- REPAIR AND WILL REQUIRE RE-INSPECTION AT 1,000 HOUR INTERVALS, LIFE LIMIT IS 6,000 HOURS IAW SRM 53-30-03 FIG 1 SHEET 14 TABLE V.