What was found
DURING CRUISE HYD 3 ELEV "OFF" LIGHT ON. HYD QTY CHECKED 4.2 GAL AND KEPT ON DROPPING TO BELOW 2.5 GALS. HYD 3 FAIL. DIVERTED TO VCP, LANDING NORMAL. MX FOUND O-RING CUT ON HYD FILTER MODULE. REMOVED AND REPLACED O-RING IAW 20-40-02. SERVICED NR 3 HYD IAW 12-13-02, RUN UP AND LEAK CHECK GOOD IAW 29-00-00 PG 216. A/C RELEASED FOR SERVICE.