What was found
DURING TAKEOFF ROLL, CREW RECEIVED A LEVEL 2 ALERT ON THE EAD WITH A MASTER CAUTION LIGHT FOR ENGINE N1, RPM HIGH. DISCONTINUED TAKEOFF. MAXIMUM N1 RPM RECORDED WAS 111.6. NO FURTHER INCIDENT. FOLLOWED PROCEDURES IN FIM 77-11-06, INSPECTED ENGINE. NO FAULTS NOTED. REPLACED EEC IAW AMM 71-02-07 & AMM 71-02-06, RAN NR 2 ENGINE. OP CHECKED GOOD AND ACFT RETURNED TO SERVICE.