What was found
AFT BAGGAGE BAY FLOOR STRUCTURE @ FS1047.00 AFT OF DOOR STRUCTURE. INTERCOSTAL PN:MM670-35372-005 HAS MODERATE CORROSION. REMOVED MODERATE CORROSION ON INTERCOSTAL C/T AFT BAGGAGE BAY FLOOR STRUCTURE @ FS 1047 IAW CRJ 700 SRM 51-21-06-001-001-A01. GRIDDED AREA AND SIGNED UP FOR NDT EDDY CURRENT INSPECTION COMPLETED AND NO CRACKS FOUND (SEE ATTACHMENT NIAR F291024.PDF) REMOVED AND REINSTALLED NUTPLATE IAW CRJ 700 SRM 51-45-00-001-001-A01 REMOVED AND REPLACED 3 BLENDED OVER FASTENERS WITH NEW IAW CRJ 700 SRM 51-42-06-001-001-A01 ALODINED, PRIMED, & PAINTED BARE METAL SURFACE IAW CRJ700 SRM 51-21-16-001-001-A01. ALL WORK COMPLETED IAW EA NO: A1-670-53-00121 REV --.