DURING MAINTENANCE PANEL 326AL WAS FOUND WITH DAMAGE TO THE COPPER MESH ON THE EXTERNAL SURFACE. SANDED DAMAGED AREA TO REMOVE BONDED MESH. CLEANED AREA TO REMOVE ANY DUST. CUT PLIES TO FIT AREA.