What was found
CORROSION FOUND ON SUBSTRUCTURE AT FS 847.00 - FS 847.00+32.00 LH BL 36.00 ALONG BOTTOM STRAP. REMOVED CORROSION ON SUBSTRUCTURE AT FS 847.00 - FS 847.00+32.00 LH BL 36.00 ALONG BOTTOM STRAP IAW CRJ900 SRM 51-21-06-001-001-A01. FABRICATED STRAP SH670-39347-7 FROM 2024-T3 LOT# 585873B3/1.1, LOCATED AND DRILLED IAW CRJ900 SRM 51-40-11-001-001-A01, SRM 51-24-36-001-001-A01. REPLACED STRAP SH670-39347-7 WITH NEW FABRICATED STRAP IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-15-001-001-A01.