What was found
SURFACE CORROSION ON FWD SIDE OF FRAME 394.00 BETWEEN STRINGERS 24R AND 23R, NEXT TO FASTENER. REMOVED CORROSION ON FWD SIDE OF FRAME 349,00 BETWEEN STGR 23RH-24RH IAW CRJ900 SRM 51-21-06-001-001-A01. ROTO PEENED REWORKED AREA IAW CRJ 900 SRM 51-24-11-001-001-A01 AND REO 690-53-21-1923 REV --. RESTORED FINISH IAW CRJ 900 SRM 51-25-06-001-001-A01, 51-25-16-001-001-A01, & 51- 21-11-001-001-A01. ALL WORK COMPLIED WITH MHIRJ REO 690-53-21-1923 REV --.