What was found
DURING INSPECTION, TASK 000-53-900-503-A01, THE SHOP FLOOR FOUND FRAME AT FS 310.00, STR 27 AND 26L CORRODED, FILAFORM, OUT OF LIMITS IAW SRM 53-21-06-101-002-A01, 53-00-00-101-001-A01. REMOVED AND INSTALLED A NEW SERVICABLE FRAME AT FS 310.00, STR 23L TO 23R IAW REO 670-53-21-799 REV.