What was found
WHILE PERFORMING SB 670BA-53-045, REV D FOUND 4 EACH EXISTING FASTENER HOLES TO BE PITCHED INTO RADIUS OF LT FS 220.0 FRAME SECTOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE PERFORMING SB 670BA-53-045, REV D FOUND 4 EACH EXISTING FASTENER HOLES TO BE PITCHED INTO RADIUS OF LT FS 220.0 FRAME SECTOR.