What was found
DURING BOW 1C/3C/S2/S4, FOUND CORROSION ON SUBFLOOR AT STA 196-198 RBL 4 TO LBL 4. REPAIRED PER ESO 80559, AARD 53-20-00-16. ADDRESSED AS REQUIRED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING BOW 1C/3C/S2/S4, FOUND CORROSION ON SUBFLOOR AT STA 196-198 RBL 4 TO LBL 4. REPAIRED PER ESO 80559, AARD 53-20-00-16. ADDRESSED AS REQUIRED.