What was found
DURING BOW 1C/3C/S2/S4, TWO EACH HOLES IN CUSP MEMBRANE AT FWD ENTRY DOOR AREA STA 160-196. CUT OUT DAMAGE AREA AND INSTALLED DOUBLER PER AARD 53-20-00-16. ADDRESSED AS REQUIRED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING BOW 1C/3C/S2/S4, TWO EACH HOLES IN CUSP MEMBRANE AT FWD ENTRY DOOR AREA STA 160-196. CUT OUT DAMAGE AREA AND INSTALLED DOUBLER PER AARD 53-20-00-16. ADDRESSED AS REQUIRED.