SDR WX0A071057

Service difficulty report · Regulator Valve · Doug DC982

Difficulty date
January 4, 2012
Submitted
January 12, 2012
Operation
Air carrier
Aircraft
N425NV
Make and model
Doug DC982
Aircraft serial
49438
Part
Regulator Valve
Part number
39271411
Condition
Faulty
Location
Ac Bay
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF F/A NOTIFIED FLIGHT CREW OF SMOKE IN THE CABIN. ALL SYSTEM AND INDICATION NORMAL, BOTH TEMP PACK GAUGES WERE BOTH INDICATING AT THE 2 O`CLOCK POSITION. AFTER 10 MINUTES, SMOKE CLEARED. MAINTENANCE DEPARTMENT PERSONNEL TROUBLESHOT TO THE RIGHT PACK TEMP CONTROLLER, MANUAL WORKS NORMAL. REMOVED AND REPLACED AIR CONDITIONING PRESSURE REGULATOR VALVE, RIGHT SIDE. PERFORMED ADJUSTMENT AND TEST REF MM 21-31-01, NO FAULT NOTED. AIRCRAFT RETURNED TO SERVICE.