What was found
AFT PIT CARGO DOOR CUTOUT FWD WEB CORRODED STATION 1150 BETWEEN LONGERONS 23R & 25R. CUTOUT DAMAGED AREA, FABRICATED, LOCATED, DRILLED & INSTALLED WEB SECTION IAW SRM 53-01 FIGURE 4 SHEET 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT CARGO DOOR CUTOUT FWD WEB CORRODED STATION 1150 BETWEEN LONGERONS 23R & 25R. CUTOUT DAMAGED AREA, FABRICATED, LOCATED, DRILLED & INSTALLED WEB SECTION IAW SRM 53-01 FIGURE 4 SHEET 4.