What was found
(EMERGENCY DECLARED) F/CTL FLAPS FAULT ECAM WHEN SELECTING FLAPS 2 ON BASE. ECAM AND CHECKLIST WERE ACCOMPLISHED.LANDING AND ROLL OUT WAS NORMAL, BRAKES GOT TO 500 DEG C AFTER LANDING, NO ISSUES DURING COOLING // PERFORMED A BITE TEST OF SFCC1/2 IAW AMM 27-51-00-740-002-A, NO FAULTS DETECTED, PERFORMED OPERATIONAL CHECK OF THE FLAP SYSTEM IAW AMM 27-54-00-710-001-A, OPS CHECK NORMAL, AC OK FOR SERVICE."