As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
XTERNAL FUSELAGE BTW FR79-FR80 AND STGR2-3 L/H NEED PERMANENT REPAIR WITHIN 500 FC- ACCOMPLISHED STS EA 72-2023-018 PERM REPAIR REQ, SRM TASK 53-51-11-300-064. / EXTERNAL FUSELAGE BTW FR79-FR80 AND STGR2-3 L/H PERMANENTLY REPAIRED AS PER SRM TASK 53-51-11-300-064 REV. 145. AND COMPLY WITH STS EA 72-2023-018 .REPAIR CATEGORY A. NO FURTHER ACTION REQUIRED. SEE AWS FOR DETAIL OF WORK ACCOMPLISHED AND NDT REPORT MWO55713-1"