What was found
(MAJOR REPAIR) AT R1 FWD GIRT BAR FITTING AREA, FWD OUTBD HOLE FOUND CORRODED / R1 DOOR SILL BEAM FWD GIRT BAR FITTING AREA, FWD OUTBD HOLE PERMANENTLY REPAIRED PER SRM 53-11-14-283-005 REV.146. REPAIR CATEGORY B, SEE SRI 53-11-14-205-001 REV.146 FOR INSPECTION REQUIREMENTS, INSPECTION THRESHOLD: 60000FC FROM AIRCRAFT FIRST FLIGHT, SUBSEQUENTINSPECTION INTERVALS: TBD, INSPECTION METHOD: TBD. SEE AWS FOR DETAILS. SEE EO E5311-0020 FOR GIRT BAR FITTING INSTALLATION."