What was found
NRC 2000-0001: (274-2) JUST FWD OF R/H WINDSHIELD, BTWN FR3-4, DENT FOUND. / JUST FWD OF R/H WINDSHIELD BTW FR 3-4, DENT FOUND WITHIN LIMITS IAW SRM 53-00-11-283-005. REPAIR CATEGORY B, SEE SRI 53-00-11-205-050 FOR INSPECTION REQUIREMENTS. INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT: 60000FC/120000FH, SUBSEQUENT INSPECTION AT INTERVALS OF: TBD, INSPECTION METHOD: TBD. DENT DIMENSIONS: LENGTH: 2.900IN, WIDTH: 1.300IN, DEPTH: 0.032IN, A: 0.660IN, SKIN THICKNESS: 0.079IN, D/A 0.1? 0.032 0.066. SEE AWS FOR DETAIL."