What was found
(EMERGENCY DECLARED) ON APPROACH FLT CNTL FLAPS FAULT RAN ECAM ATTEMPTED FLAP RESET BY SELECTING PREVIOUS POSSITION FLAP FAULT REMAINED. PERFORMED TSM 27-51-00-810-810-A, FLAP SYSTEM JAM, FOUND TRIPPED TORQUE LIMITER INDICATOR ON L/H WING OF ACTUATOR ASSY 1, PER TSM 27-51-00-810-810-A REQUIRES ROTARY ACUTATORS WITH TRIPPED INDICATORS TO BE REPLACED, NO DISCREPANICES FOUND DOWNSTREAM.REMOVED L/H TRACK 1 ACUTATOR ASSEMBLY FIN (6205CM) P/N 791A0000-06 S/N V8616 PER AMM 27-54-49-000-001-A, INSTALLATION REQUIRED.INSTALLED FLAP TRACK 1 ACTUATOR ASSY IAW: AMM 27-54-49-400-001-A OPS CHECK GOOD.