AFT CARGO DOOR JAMB BEAM CORRODED AT STATION 1155 TO 1212. FOUND WHILE WORKING DROP-IN NON-ROUTINE M301 ITEM. CUT OUT DAMAGED AREA OF BEAM. HFEC INSPECTED WITH NO CRACKS NOTED. FABRICATED REPAIR PARTS. LOCATED, DRILLED AND INSTALLED.