What was found
R1 DOOR FLOOR WEB IS CORRODED FROM STATION 180 TO 200 RBL 44 TO 54. REPAIRED CUSP WEB IAW SRM 51-70-4 FIG 2. WORK ACCOMPLISHED ON WORK ORDER 1011048-2400-0138 M301 ITEM 331.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR FLOOR WEB IS CORRODED FROM STATION 180 TO 200 RBL 44 TO 54. REPAIRED CUSP WEB IAW SRM 51-70-4 FIG 2. WORK ACCOMPLISHED ON WORK ORDER 1011048-2400-0138 M301 ITEM 331.