What was found
MAIN CABIN FLOORBEAM UPPER FLANGE IS CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL 3. REPAIRED IAW SRM 53-00-51 FIG 201 REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOORBEAM UPPER FLANGE IS CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL 3. REPAIRED IAW SRM 53-00-51 FIG 201 REPAIR 1.