What was found
FLOORBEAM AT FS 256 HAS CORROSION BETWEEN RBL 22 & RBL 44. FABRICATED & INSTALLED FLOOR SUPPORT IAW SRM 51-10-4 & 51-30-5, WITH 4½ LENGTH 1½ ORIGINAL .070 REMAINING 0. LEVEL 2 WORK ACCOMPLISHED ON WO 243433 M301 ITEM 530 & WO 1011609 2000-0183.