What was found
FLOORBEAM AT FS 256 HAS CORROSION BETWEEN LBL 22 & RBL 22. FABRICATED & INSTALLED FLOOR SUPPORT IAW SRM 51-10-4 & 51-30-5 WITH 2 1/2 LENGTH 1 1/2 ORIGINAL .070 REMAINING 0 LEVEL 2. WORK ACCOMPLISHED ON WO 243433 M301 ITEM 529 & WO 1011609 2000-0182.