What was found
TWO EACH CRACKS FOUND ON LT WING LE, APPROX 8 INCHES OTBD OF NR 2 SLAT, CTR TRACK. ONE IS APPROX 0.50"" & THE OTHER 3.75 INCHES LONG. PERFORMED EA 20-2015-167 SECTION I STEPS 1, 2 & 3 ON LOG PAGE 612426. PERFORMED FLUORESCENT PENETRANT INSPECTION IAW NDT SPM, CRACK HAS NOT ELONGATED PAST STOP DRILL. SEE LOG PAGE 612425 FOR DEFERRAL PROCEDURES & REPETITIVE INSPECTION.