What was found
EMERGENCY DECLARED DUE TO OVERWEIGHT LANDING FOR MX DIVERSION FOR OIL STRAINER CLOGGING. LT OIL STRAINER CLOGGING ANNUNCIATOR ILLUMINATED ON CLIMB OUT. ACCOMPLISHED QRH PROCEDURE 72.16. ANNUNCIATOR EXTINGUISHES AT 1.3 EPR & RE-ILLUMINATES ABOVE 1.3 EPR. OIL PRESS WAS GOOD HOWEVER OIL TEMP WAS ELEVATED TO 125 AT IDLE & AT 1.3 EPR. OIL TEMP APPEARED NORMAL. REPLACED MAIN OIL FILTER, NO DEFECT NOTED LEAK CHECK OK. PLACED ON MEL 79-05 S1. OIL LEVEL CHECK AT 12 QTS PLACARD INSTALLED.