What was found
THE PRIMARY TRIM NOT WORKING ON CLIMB OUT & LEVEL OFF FOR 10 MINUTES. TROUBLE SHOT SYS & FOUND LONGITUDINAL TRIM & OVERRIDE CONTROL UNIT BINDING AT LINKAGE WHEN PUSHING SUIT CASE RT HANDLE FWD OR AFT, PART ON ORDER. R & R PRIMARY LONGITUDINAL TRIM CONTACTORS & OVERRIDE & SHUTOFF CONTROL IAW AMM 27-40-04 UP TO STEP 4 B 9. OPERATIONS CHECK STILL REQUIRED. PERFORMED TEST OF TRIM INDICATING & SHUTOFF CONTROLS IAW 27-40-00-5-0 PG 15. SYS TESTED GOOD.