What was found
GREEN HYD RESERVOIR LOW WITH GREEN SYS PRESS LOW ECAM, RAN ECAM & QRH. PERFORMED MANUAL GEAR EXTENSION & FOUND PIN HOLE RUBBED IN LINE FROM CLAMP. LINE PN 112441-507, REPLACED LINE IAW AMM 29-11-49. LEAK & OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GREEN HYD RESERVOIR LOW WITH GREEN SYS PRESS LOW ECAM, RAN ECAM & QRH. PERFORMED MANUAL GEAR EXTENSION & FOUND PIN HOLE RUBBED IN LINE FROM CLAMP. LINE PN 112441-507, REPLACED LINE IAW AMM 29-11-49. LEAK & OPERATIONS CHECKED GOOD.