As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
IN FLIGHT RECEIVED GREEN HYD LOW LEVEL ECAM. COMPLIED WITH ECAM ACTIONS. AFTER EXTENDING LANDING GEAR, GREEN HYD FLUID LEVEL INCREASED HALF WAY UP TO GREEN BAND. LANDED NORMAL & TAXIED TO GATE NORMAL. REPLACED PTU MANIFOLD IAW AMM 29-11-15. SERVICED HYD SYSTEM GREEN SYSTEM WITH 5 GALLONS OF FLUID IAW AMM 12-12-00. PERFORMED OPS TEST OF GREEN HYD SYSTEM IAW AMM 29-11-00. TEST GOOD. OPS AND LEAK TEST OF PTU MANIFOLD GOOD IAW AMM 29-11-15.