Service difficulty report · Control Unit · Airbus A319111
FAA SDR system
- Difficulty date
- February 11, 2020
- Submitted
- February 19, 2020
- Operation
- Air carrier
- Make and model
- Airbus A319111
- Aircraft serial
- 2556
- Aircraft time
- 44,429 hours, 33,132 cycles
- Part
- Control Unit
- Part number
- 786A000012
- Part serial
- 786A00L1005415
- Condition
- Malfunctioned
- Location
- Te Flaps
- Stage of operation
- DE
- How discovered
- O
- Nature of condition
- J
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY DECLARED) ON APPROACH RECEIVED ECAM F/CTL FLAPS FAULT / REPLACED FLAP-PCU"
More about the Airbus A319-111