Service difficulty report · Power Supply · Airbus A319111
FAA SDR system
- Difficulty date
- June 22, 2021
- Submitted
- June 23, 2021
- Operation
- Air carrier
- Make and model
- Airbus A319111
- Aircraft serial
- 2821
- Aircraft time
- 44,492 hours, 32,916 cycles
- Part
- Power Supply
- Part number
- 321431
- Part serial
- 862786
- Condition
- No Test
- Location
- Emergency Lights
- Stage of operation
- IN
- How discovered
- C
- Nature of condition
- L
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WAKING UP A/C NOTICED FWD EMERGENCY CABIN LIGHTS ON. / C/W OPS CHECK OF EMERGENCY POWER SUPPLY UNITS BY BITE CHECK REF A319 AMM 33-51-00-710-001A. EPSU BAT 10WL FAILED. REMOVED AND REPLACED EPSU BATTERY 10WL REF A319 AMM 33-51-38 PB401. OPS CHECK GOOD."