What was found
BAT/EPSU (12WL) EMER R CLASS 1 FAULT DURING EPSU SYS TEST. / REMOVED AND REPLACED BATTERY AT EPSU 12WL IAW AMM 35-51-38-000-002-A AND 35-51-38-400-002-A. PERFORMED BITE TEST IAW AMM 35-51-00-710-001. OPS CHECK GOOD."
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BAT/EPSU (12WL) EMER R CLASS 1 FAULT DURING EPSU SYS TEST. / REMOVED AND REPLACED BATTERY AT EPSU 12WL IAW AMM 35-51-38-000-002-A AND 35-51-38-400-002-A. PERFORMED BITE TEST IAW AMM 35-51-00-710-001. OPS CHECK GOOD."