What was found
EPSU BATTERIES FAILED AT FIN 10WL AND 12WL. REMOVED AND REPLACED EPSU BATTERIES AT POSITIONS 10WL AND 12WL IAW A319 AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EPSU BATTERIES FAILED AT FIN 10WL AND 12WL. REMOVED AND REPLACED EPSU BATTERIES AT POSITIONS 10WL AND 12WL IAW A319 AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. OPS CHECK GOOD.