DURING WEEKLY CHECK OF EPSU SYSTEM, FOUND EPSU AT FIN 13WL FAULTING ON BITE TEST. REMOVED AND REPLACED EPSU BATTERY. OPS TEST GOOD. NO FURTHER DISCREPANCIES NOTED. REF AMM 33-51-38-000-002-A AND 33-51-38-400-002-A.