What was found
EMERGENCY LIGHTS AT LEFT OVERWING AND L2,R2 EXITS ARE INOP WHEN ON BATTERY POWER / REMOVE AND REPLACE AFT, LEFT, AND RIGHT BATTERY OF THE EMERGENCY POWER SUPPLY UNIT W/REF AMM 33-51-38-000-002-A."
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS AT LEFT OVERWING AND L2,R2 EXITS ARE INOP WHEN ON BATTERY POWER / REMOVE AND REPLACE AFT, LEFT, AND RIGHT BATTERY OF THE EMERGENCY POWER SUPPLY UNIT W/REF AMM 33-51-38-000-002-A."