What was found
DURING OPS CHECK ON EPSU FOUND 11WL AND 12WL FLAGGING FOR EXTERIOR EMERGANCY LIGHTS AND 11WL AND 12WL EPSU PANEL STILL OPEN / REMOVED AND REPLACED EMERGENCY OVERWING LIGHTBULBS AT 62WL AND 63WL REF AMM 33-51-15-000-001-A AND AMM 33-51-15-400-001-A.CLOSED EPSU PANELS 241KW AND 242KW REF AMM 25-23-44-400-001"