What was found
DISCREPANCY NOTED DURING HEAVY MX VISIT) NRC 2000-0040: (34240-07)(S/M) L1 DOOR SILL, UNDER FWD AND AFT GIRT BAR FITTINGS, CORROSION FOUND AROUND ALL FASTENERS ATTACHMENT HOLES, QTY 8X, L1 DOOR SILL, UNDER FWD AND AFT GIRT BAR FITTINGS ALL FASTENERS ATTACHMENTS HOLES (QTY.8) PERMANENTLY REPAIRED PER SRM 53-11-14-283-005 REV.148. REPAIR CATEGORY B, SEE SRI 53-11-14-205-001 REV.148 FOR INSPECTION REQUIREMENTS, INSPECTION THRESHOLD: 60000FC FROM AIRCRAFT FIRST FLIGHT, SUBSEQUENT INSPECTIONS INTERVALS: TBD, INSPECTION METHOD: TBD. SEE AWS FOR DETAILS. SEE E5311-0020 FOR GIRT BAR FITTINGS INSTALLATION.