Service difficulty report · Receptacle · Airbus A320214

Difficulty date
September 13, 2024
Submitted
September 25, 2024
Operation
Air carrier
Aircraft
N238NV
Make and model
Airbus A320214
Aircraft serial
2133
Aircraft time
66,885 hours, 26,175 cycles
Part
Receptacle
Condition
Corroded
Location
Proximity Sensor
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(AIRCRAFT NOT GROUNDED) PASSING 10,000 R1 DOOR OPEN INDICATION ON ECAM. PRESSURIZATION NORMAL FOR FLIGHT / PER TSM 52-11-00-810-803-A FOUND CORROSION ON RECEPTACLE OF PROX SENSOR 13WV2. REMOVED AND REPLACED PROX SENSOR 13WV2 IAW AMM 52-71-11-000-001 AND AMM 52-71-11-400-001. OPS CHECK GOOD. THIS CLEARS MEL 52-70-01-A MDDR 200952."