Service difficulty report · Smoke Detector

Difficulty date
December 11, 2017
Submitted
December 12, 2017
Operation
General aviation
Filed by
X3TR865J
Curtiss-Wright DS Inc
Part
Smoke Detector
Part number
33011
Part serial
5479
Condition
Out Of Adjust
Location
Cargo Bay
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE SMOKE DETECTOR WAS RECEIVED AT OUR REPAIR FACILITY FOR RETROFIT FROM P/N 3301-1 TO P/N 3301-21. DURING THE RETROFIT PROCESS AN INCOMING TEST WAS PERFORMED AND THE DETECTOR DID NOT MEET THE OEM (FACTORY)REQUIREMENTS OF ALARM SETTING: 96.5 +/- 1% TRANSMISSIBILITY, THE UNIT RESULT OF THE ALARM TEST WAS 93.0%. CURTISS-WRIGHT HAS DETERMINED THIS IS NOT A SAFETY ISSUE AS THE UNIT MEETS FAA TSO TYPE II REQUIREMENTS OF ALARM LEVEL OF 60%-96% LIGHT TRANSMISSION/FOOT.