What was found
FLAPS JAMMED AT 6 DEGREES DURING RETRACTION AFTER TAKEOFF. FLAP JAM AMBER CAS MSG ILLUMINATED. PERFORMED CHECKLIST FOR FLAP JAM & DIVERTED. TECH OPS INFORMED US THAT THIS IS A KNOWN ISSUE & IS ADDRESSED IN 2 MX OPERATIONS LETTERS. MOL 14-0012 DATED 12/30/2014 DESCRIBES A FLAP RETRACTION PROCEDURE THAT MINIMIZES THE POTENTIAL FOR A FLAP JAM MSG. MOL 15-0005 DATED 3/19/2015 CLARIFIES THE RETRACTION PROCEDURE & ADDS A PROCEDURE TO RESET THE FLAPS IF A FLAP JAM MSG OCCURS UNDER CERTAIN CIRCUMSTANCES. MX PERFORMED THE FLAP RESET PROCEDURE & PERFORMED MULTIPLE OPERATIONAL CHECKS OF THE FLAPS WITH NO DEFECTS NOTED.