What was found
L2 DOOR SILL CORRODED INBD OF GIRT BAR. CUTOUT AREA AND FABRICATED ANGLE REPAIR IAW SRM 53-41-14. PERFORMED HFEC INSPECTION AT CUTOUT AND IAW NTM 51-10-01 PB. NO CRACKS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L2 DOOR SILL CORRODED INBD OF GIRT BAR. CUTOUT AREA AND FABRICATED ANGLE REPAIR IAW SRM 53-41-14. PERFORMED HFEC INSPECTION AT CUTOUT AND IAW NTM 51-10-01 PB. NO CRACKS NOTED.